Best UPS for Synology NAS

A Synology NAS backup plan is less about keeping the box running for hours and more about preventing dirty shutdowns, interrupted writes, and avoidable storage recovery work. The right UPS gives DSM enough time to detect the outage, notify the NAS, and perform a clean shutdown while still leaving headroom for switches, routers, or related network gear.

Start with the exact NAS compatibility list and a shutdown plan. A UPS must power the NAS and communicate the outage to DSM. Extra battery capacity does not substitute for either requirement. For most home NAS installations, a dependable window to stop services and protect storage is the first objective.

Which UPS models are worth checking?

Use Synology’s compatibility selector for your exact NAS, then match the complete UPS model suffix and region. The following examples come from the DS923+ / CyberPower list; they are not blanket approvals for every Synology NAS. Pay attention to the “Tested by” column: a vendor recommendation is a different evidence level from a Synology test.

Exact model listed for DS923+Status shown in the source listHow to use that information
CyberPower CP1000PFCLCDVendor RecommendedA candidate for a modest measured load; check current unit revision, runtime and direct USB detection. BBB model record.
CyberPower CP1500PFCLCDVendor RecommendedAnother candidate where the measured load and shutdown window warrant it. Confirm its own runtime curve and current hardware. Manufacturer model information.
CyberPower BRG1500AVRLCD2SynologyAn example of a different test-status entry. Do not transfer that status to other CyberPower models or another NAS.

Synology notes that hardware or firmware changes can affect compatibility. Recheck the live selector before purchase, and keep the exact suffix: CP1350PFCLCDa, for example, is not the same model text as CP1350PFCLCD. We have not tested these combinations.

Size the complete storage and network path

Include the NAS, expansion enclosures or other powered storage it needs, and the network devices carrying UPS notifications. A directly connected USB UPS can signal one NAS without internet access. A network UPS arrangement also needs the relevant switch to stay powered. Add the router and modem or ONT only when your required access or notification path depends on them.

Measure the complete AC load during representative storage activity and account for startup demand. Check the UPS watt and VA limits separately. Select runtime using the manufacturer’s curve, leaving time for your storage workload to quiesce and for battery aging. The NAS adapter’s maximum rating is not a measured average draw.

For illustration, a measured 60 W storage load plus 15 W of necessary networking is a 75 W UPS load before adding other equipment. Look up runtime at that load for the exact UPS. Do not divide “1500 VA” by 75 W and call the result hours: VA is not stored energy.

Configure DSM 7 with a USB UPS

  1. Power the NAS from a battery-backed UPS outlet and connect the UPS data cable directly to a NAS USB port. Synology does not support a USB hub for this connection.
  2. Open Control Panel → Hardware & Power → UPS, enable UPS support and select USB UPS.
  3. Use Device Information to check detection. Choose the time before DSM enters Standby Mode, then apply the settings.
  4. If you want automatic recovery, review Restart automatically after a power failure under the General tab. Test it with the UPS’s actual power-restoration behavior.

In DSM 7, Standby Mode stops services and unmounts volumes. A low-battery signal can trigger it before your chosen timer expires. UPS power-off commands are model-dependent, so enabling that option is not proof that the UPS will obey it.

Choose the right signaling arrangement

ArrangementPractical fitWhat must remain working
Direct USBOne NAS near the UPSThe UPS data connection and that NAS.
Synology network UPS serverOne NAS relays status to other permitted Synology NAS devicesThe server NAS, clients and switch carrying the messages. Configure permitted client IP addresses and the server address on clients.
SNMP UPSA UPS with supported network management for a networked installationCompatible management hardware, DSM settings and the powered network path. An Ethernet surge-protection jack is not a management card.

Follow DSM’s documentation for the selected arrangement. For a high-availability cluster, use the separate Synology HA guidance and check both hosts; a plan for a single home NAS does not establish cluster behavior.

Verify the shutdown window before relying on it

Maintain a separate backup of important data, finish active work and schedule a controlled test. Follow the UPS maker’s permitted outage-test procedure and Synology’s UPS setup instructions. Record the UPS model and serial number, NAS model, DSM version, load and settings.

  1. Confirm DSM reports the transition to battery.
  2. Confirm every network UPS client also receives the event while the switch remains powered.
  3. Observe whether services stop and volumes unmount before the battery reaches exhaustion.
  4. If enabled, verify the UPS-off command actually works on that model.
  5. Restore normal power and check the intended NAS restart and storage status.

Repeat the relevant checks after changes to the battery, UPS hardware, communication settings, DSM or the protected equipment. A UPS reduces abrupt-power-loss risk; it does not replace backups or prove that a storage array cannot lose data.

Common questions

Do I need hours of runtime?

Only if continued service is your goal and the complete installation can support it. For orderly shutdown, choose enough measured runtime to complete that process with reserve. A larger rating alone does not specify the shutdown window.

Can I use a portable power station?

A station may power the NAS, but its transfer time, bypass limits, low-load behavior and supported shutdown signaling need separate verification. See power stations and UPS switchover.

Can I share a UPS with a desktop?

Yes, if the electrical load and each device’s shutdown arrangement are supported. A single direct USB connection does not automatically tell both devices to shut down. Plan the signaling before adding loads.

Continue with the PC UPS setup guide and product comparison tool.

Sources and research method

Manufacturer documentation checked November 2, 2026. This is a research guide, not a report of hands-on testing. Exact model, region, hardware and manual revision matter.

Scroll to Top